Heat Inspection
REsidential Gas Furnace
Note thermostat settings.
Replace filter, write date on filter. Wash filter, if washable.
Put in heat and raise to 80 degrees.
TURN POWER OFF.
ELECTRONIC AIR CLEANER, if covered: TURN OFF. Replace filter media. If washable, wash filter thoroughly with chemicals, rinse and reinstall. Instruct customer to TURN BACK ON the next day.
Brush inside of heater and blower compartment.
Check blower assembly for cleanliness and force spin.
Tighten all wires.
Inspect all wiring and electrical components, e.g. contactors, relays, and run capacitor.
Start furnace.
Inspect inducer motor (if applicable).
Inspect and clean flame sensor.
Inspect hot surface ignitor pressure switches, rollout switches, limit switch and any other safety.
Blow out drain from secondary heat exchanger and traps. Inspect burner box and jets for cleanliness.
Test condensate pump (if applies and add pan tabs) and test pan switch.
Check burner fire and flame color (should be blue).
Take CO reading in space AND in flue. Check flue temperature. Print out receipt and place in service log ziplock.
Check Delta T and CO test. Confirm Delta T is within Manufacturers’ specifications.
If natural draft, check cleanout & clear debris and inspect flue pipe.
HUMIDIFIER, if covered: Open damper, start, test, and set humidistat to 35 percent. Confirm clean water panel in place.
Reset thermostat to original temperature and wipe down.
Make sure all switches and disconnects are turned back on.
Wipe down outside of unit with cleaner.
RESET SYSTEM and clean up area.
Screenshot Model & Serial Numbers for new customers or for existing customers when parts or replacement unit is needed.
Fill out service log, if not present attach to unit.
Place J&B foil label on OD unit if not already there. Replace existing label if worn.
Explain findings to customer and suggest any upgrades or replacements that are appropriate.
Advise customer that invoice will follow via email.
Thank customer for their business!
Populate work order on tablet. List all parts & materials used. Upload any images.
Note any work that needs to be done.
Note general condition of major components and approximate age of equipment.
Reset